Electrical glossary, English and Spanish

Texas lets you take the exam in Spanish, but the job site, the code book and your crew mix both languages. Every term has its pair in the other language, a short definition and, where it applies, the 2026 NEC article and a calculation drill.

Theory

Alternating current (AC) Corriente alterna (CA)
Current that reverses direction many times a second. In the United States it alternates at 60 hertz.
Current Corrientealso: intensidad de corriente
The flow of electric charge through a conductor, measured in amperes (A). Formulas write it as I.Practice →
Delta connection Conexión deltaalso: triángulo
A three-phase connection with the windings joined end to end in a closed loop. Line voltage equals winding voltage.Practice →
Direct current (DC) Corriente directa (CD)also: corriente continua (CC)
Current that flows in one direction only, as from a battery or a PV module.
Efficiency Eficienciaalso: rendimiento
Output power divided by input power, as a percentage. A motor that is 90% efficient turns 10% of its input into heat.Practice →
Harmonics Armónicasalso: armónicos
Currents at multiples of 60 Hz produced by nonlinear loads. On wye systems they can add up in the neutral, so the neutral may count as current-carrying.
High leg Fase altaalso: fase de mayor tensión (high leg)
On a 4-wire delta system with a center-tapped winding, the phase with the higher voltage to ground (about 208 V on a 240/120 V system). It must be marked orange.NEC 110.15Practice →
Impedance Impedancia
The total opposition to alternating current, combining resistance and reactance, measured in ohms (Z).
Nominal voltage Tensión nominalalso: voltaje nominal
The round-number voltage used to name a system, such as 120/240 V or 480Y/277 V. Actual voltage varies a little above or below it.NEC Article 100
Ohm's law Ley de Ohm
The rule that voltage equals current times resistance (E = I × R). Rearranged, it finds any one value from the other two.Practice →
Parallel circuit Circuito en paralelo
A circuit with several branches across the same voltage. Total resistance is lower than the smallest branch resistance.Practice →
Power Potencia
The rate at which electrical energy is used or delivered, measured in watts. In a resistive circuit, P = E × I.Practice →
Power factor Factor de potencia
The ratio of true power (W) to apparent power (VA), from 0 to 1. A low power factor means more current for the same useful work.Practice →
Resistance Resistencia
Opposition to current flow in a material, measured in ohms. Longer and smaller conductors have more resistance.Practice →
Series circuit Circuito en serie
A circuit with only one path, so the same current flows through every part. Total resistance is the sum of all resistances.Practice →
Three-phase Trifásico
A system with three voltages 120 degrees apart. Power formulas for it include the square root of 3 (1.732).Practice →
True power Potencia realalso: potencia activa
The power that does actual work or makes heat, measured in watts. It equals apparent power times power factor.Practice →
Volt-ampere (VA) Voltampere (VA)also: volt-amperio
The unit of apparent power, volts times amperes. Load calculations are done in VA, and transformers are rated in kVA.Practice →
Voltage Voltajealso: tensión
The electrical pressure that pushes current through a circuit, measured in volts (V). Formulas write it as E or V.Practice →
Voltage to ground Tensión a tierraalso: voltaje a tierra
For a grounded system, the highest voltage between a given conductor and the grounded point or conductor of the circuit.NEC Article 100
Wye connection Conexión estrellaalso: estrella (Y)
A three-phase connection with one end of each winding joined at a common neutral point, as in 208Y/120 V or 480Y/277 V. Line voltage is 1.732 times phase voltage.Practice →

Conductors

AC cable Cable armado tipo ACalso: BX
Armored cable with a metal armor and an internal bonding strip, so the armor can serve as the equipment grounding path. Old trade name: BX.NEC Article 320
Adjustment factor Factor de ajustealso: derrateo, ajuste por agrupamiento
A factor that lowers ampacity when more than three current-carrying conductors share a raceway or cable, because they heat each other. In the trade, applying it is called derating.NEC 310.15(C)(1)Practice →
Ambient temperature correction Corrección por temperatura ambientealso: factor de corrección
A factor that lowers ampacity when the surrounding air is hotter than the 30°C (86°F) the ampacity table assumes.NEC 310.15(B)Practice →
American Wire Gauge (AWG) AWG (calibre)also: calibre americano de conductores
The US system of wire sizes. Smaller numbers are larger wires, and sizes above 4/0 AWG are given in kcmil.NEC Table 310.16Practice →
Ampacity Ampacidadalso: capacidad de conducción de corriente
The most current a conductor can carry continuously under its conditions of use without going over its temperature rating.NEC Article 100Practice →
Circular mil Mil circularalso: circular mil (cmil)
The area of a circle one mil (0.001 inch) across. Conductor areas in circular mils are used in voltage drop formulas.NEC Chapter 9, Table 8Practice →
Conductor color code Código de colores de los conductores
NEC identification rules: white or gray for the grounded conductor, green, green-yellow or bare for equipment grounding, and orange for a high leg.NEC 200.6
Current-carrying conductor Conductor portador de corriente
A conductor counted for adjustment factors. Equipment grounding conductors never count, and a neutral counts only in certain cases.Practice →
Flexible cord Cordón flexiblealso: cable de uso rudo
A flexible cable for connecting portable equipment and appliances. It cannot be used as a substitute for permanent wiring.NEC Article 400
Insulation Aislamiento
The nonconducting layer around a conductor. Its letter type tells the temperature rating and where the wire may be used.NEC Article 310
Insulation temperature rating Temperatura nominal del aislamiento
The highest temperature an insulation can stand continuously: 60°C, 75°C or 90°C, matching the columns of Table 310.16.NEC Table 310.16Practice →
K constant Constante Kalso: resistividad del conductor
The resistance of one circular-mil-foot of conductor, used in VD = 2KIL ÷ cmil. Common values are 12.9 for copper and 21.2 for aluminum.NEC Chapter 9, Table 8Practice →
kcmil Kcmilalso: MCM
Thousands of circular mils, the unit for conductors larger than 4/0 AWG (older term: MCM). A 250 kcmil conductor has 250,000 circular mils.NEC Table 310.16Practice →
MC cable Cable con armadura metálica tipo MCalso: cable armado MC
Metal-clad cable: insulated conductors inside a metal armor, usually with a separate green grounding conductor. Common in commercial work.NEC Article 330
Neutral conductor Conductor neutroalso: neutro (neutral)
The conductor connected to the neutral point of a system, meant to carry current under normal conditions. It is usually grounded and white or gray.NEC Article 100
NM cable Cable con forro no metálico tipo NMalso: cable Romex
Nonmetallic-sheathed cable with insulated conductors and a bare grounding wire inside a plastic jacket, mainly for dwellings and other permitted buildings. Its ampacity is limited to the 60°C column.NEC Article 334
SE cable Cable de acometida tipo SE
Service-entrance cable, used mainly for service-entrance conductors and, with conditions, for feeders and branch circuits.NEC Article 338
Termination temperature rating Temperatura nominal de las terminales
The temperature limit of the lugs on breakers and equipment. Conductor ampacity is usually taken from the 60°C or 75°C column to match it, even for 90°C wire.NEC 110.14(C)Practice →
THHN THHNalso: cable THHN
A thermoplastic-insulated conductor with a nylon jacket, rated 90°C in dry locations. It is often dual-rated THHN/THWN-2.NEC Article 310Practice →
THWN-2 THWN-2
A thermoplastic, heat- and moisture-resistant conductor with a nylon jacket, rated 90°C in both dry and wet locations.NEC Article 310Practice →
UF cable Cable tipo UFalso: cable subterráneo para alimentadores y circuitos derivados
Underground feeder and branch-circuit cable that can be buried directly in the earth. Its ampacity is limited to the 60°C column.NEC Article 340
Ungrounded conductor Conductor no puesto a tierraalso: fase, vivo
A circuit conductor that is not intentionally grounded, often called the hot or phase conductor.NEC Article 100
Voltage drop Caída de tensiónalso: caída de voltaje
The voltage lost along a conductor because of its resistance. NEC informational notes suggest about 3% for a branch circuit or feeder and 5% total.Practice →
XHHW-2 XHHW-2
A conductor with cross-linked polyethylene insulation, rated 90°C in dry and wet locations. It is common for aluminum feeders.NEC Article 310Practice →

Raceways and boxes

Box fill Llenado de cajasalso: ocupación de cajas
The calculation that checks a box is big enough for its conductors, devices, clamps and fittings, each counted as conductor volume allowances.NEC 314.16Practice →
Burial depth Profundidad de enterramientoalso: profundidad de cubierta
The minimum cover over underground cables and raceways, which depends on the wiring method and location.NEC Article 300
Bushing Monitoralso: boquilla
A fitting on the end of a conduit that protects conductor insulation from sharp edges. Insulated bushings are required for 4 AWG and larger conductors.
Cable tray Charola portacablesalso: bandeja portacables
An open support system of rails and rungs or a solid bottom for holding cables and raceways.NEC Article 392
Conduit Tubo conduitalso: tubería conduit
A round raceway of metal or plastic that protects conductors pulled through it. In the field the word covers EMT, RMC, IMC, PVC and others.Practice →
Conduit body Conduletalso: cuerpo de conduit
A fitting such as an LB, LL, LR, T or C with a removable cover that gives access to conductors at a bend or joint.NEC Article 100Practice →
Conduit fill Ocupación del tubo conduitalso: llenado de tubería
The share of a raceway's inside area that conductors may occupy: 53% for one conductor, 31% for two and 40% for three or more.NEC Chapter 9, Table 1Practice →
Electrical metallic tubing (EMT) Tubo conduit metálico ligero tipo EMTalso: tubo de pared delgada
Thin-wall, unthreaded steel tubing joined with setscrew or compression fittings. It is the most common raceway in commercial buildings.NEC Article 358Practice →
Electrical nonmetallic tubing (ENT) Tubo conduit no metálico tipo ENTalso: tubo corrugado
A corrugated, pliable plastic raceway that can be bent by hand. Electricians often call the blue version smurf tube.NEC Article 362Practice →
Flexible metal conduit (FMC) Tubo conduit metálico flexible tipo FMCalso: tubo flexible (greenfield)
Spiral interlocked metal conduit used for short flexible runs to motors and equipment. Trade name: greenfield.NEC Article 348Practice →
Handhole enclosure Registro
An underground enclosure with an open or closed bottom, big enough to reach into but not to enter.NEC Article 100
Intermediate metal conduit (IMC) Tubo conduit metálico semipesado tipo IMCalso: tubo semipesado
Threaded steel conduit with a wall thinner than RMC but thicker than EMT, permitted in the same places as RMC.NEC Article 342Practice →
Junction box Caja de empalmesalso: caja de conexiones
A box where conductors are spliced, with a removable cover that must stay accessible.NEC Article 314Practice →
Liquidtight flexible metal conduit (LFMC) Tubo conduit metálico flexible hermético a los líquidos tipo LFMCalso: tubo flexible sellado (liquidtight)
Flexible metal conduit with a liquidtight plastic jacket, used for wet or oily locations and equipment that vibrates.NEC Article 350Practice →
Nipple Niple
A short piece of raceway, 24 inches or less, between boxes or enclosures. It may be filled to 60% and needs no ampacity adjustment.NEC Chapter 9, Table 1Practice →
Outlet box Caja de salidaalso: chalupa
A box at an outlet that holds a device or supports a luminaire. Its size must satisfy the box fill rules.NEC Article 314Practice →
Pull box Caja de pasoalso: caja de jalado
A box placed in a raceway run to make pulling conductors easier. For 4 AWG and larger, its size is based on the raceway diameters entering it.NEC 314.28Practice →
PVC conduit Tubo conduit rígido de PVCalso: tubo PVC
Rigid polyvinyl chloride conduit joined with solvent cement. It resists corrosion and needs expansion fittings where temperature changes a lot.NEC Article 352Practice →
Raceway Canalizaciónalso: tubería
An enclosed channel made to hold wires, cables or busbars, such as conduit, tubing or wireway.NEC Article 100Practice →
Raceway bends Curvas en la canalizaciónalso: dobleces
The total of all bends between pull points may not exceed 360 degrees. Each raceway article has the same limit.Practice →
Rigid metal conduit (RMC) Tubo conduit metálico pesado tipo RMCalso: tubo de pared gruesa
Heavy-wall threaded steel or aluminum conduit, permitted in almost all conditions, including severe physical damage.NEC Article 344Practice →
Volume allowance Volumen por conductor
The cubic inches assigned to each conductor by size, for example 2.00 in³ for 14 AWG and 2.25 in³ for 12 AWG.NEC 314.16(B)Practice →
Wireway Ducto metálico con tapaalso: canal (wireway)
A sheet-metal trough with a hinged or removable cover, used to hold and lay in conductors.NEC Article 376

Grounding and bonding

Bonding Uniónalso: conexión equipotencial
Connecting metal parts together so they are electrically continuous and at the same potential.NEC Article 100
Bonding jumper Puente de unión
A reliable conductor that keeps electrical conductivity between metal parts that must be connected.NEC 250.102
Concrete-encased electrode Electrodo recubierto en concretoalso: electrodo Ufer
At least 20 feet of rebar or bare copper in a footing or foundation that touches the earth. Its GEC never needs to be larger than 4 AWG copper.NEC 250.52(A)(3)Practice →
Effective ground-fault current path Trayectoria efectiva de la corriente de falla a tierra
A low-impedance path built on purpose to carry fault current back to the source so the protective device opens quickly. The earth is never this path.NEC 250.4
Equipment grounding conductor (EGC) Conductor de puesta a tierra de equiposalso: cable de tierra
The conductive path that connects metal parts of equipment to the grounded conductor at the source, so a ground fault trips the breaker. Its minimum size comes from the OCPD rating.NEC 250.122Practice →
Ground Tierraalso: tierra física
The earth itself.NEC Article 100
Ground fault Falla a tierra
An unintended connection between an ungrounded conductor and grounded metal, an equipment grounding conductor or the earth.NEC Article 100
Ground rod Varilla de tierraalso: varilla copperweld
A driven rod electrode at least 8 feet long. A single rod needs a second electrode unless it measures 25 ohms or less to earth.NEC 250.52(A)(5)Practice →
Grounded Puesto a tierraalso: aterrizado
Connected to the earth or to a conductive body that extends the earth connection.NEC Article 100
Grounded conductor Conductor puesto a tierraalso: neutro (cuando es el neutro)
A system or circuit conductor that is intentionally grounded, usually the white neutral. It carries normal current, unlike the grounding conductor.NEC Article 100
Grounding conductor Conductor de puesta a tierraalso: tierra
A general term for a conductor that connects equipment or a system to ground. Do not confuse it with the grounded conductor (neutral).
Grounding electrode Electrodo de puesta a tierra
A conductive object that makes direct contact with the earth, such as a ground rod, concrete-encased electrode or metal water pipe.NEC 250.52Practice →
Grounding electrode conductor (GEC) Conductor del electrodo de puesta a tierraalso: cable a la varilla
The conductor that connects the system grounded conductor or equipment to a grounding electrode. It is sized from the largest service-entrance conductor.NEC 250.66Practice →
Grounding electrode system Sistema de electrodos de puesta a tierra
All grounding electrodes present at a building, bonded together to form one system.NEC 250.50
Intersystem bonding termination Terminal de unión entre sistemas
A device at the service that gives phone, cable TV and other communication systems a place to bond to the building's grounding system.NEC 250.94
Main bonding jumper Puente de unión principal
The connection at the service between the grounded conductor and the equipment grounding conductors. It is the only neutral-to-ground bond in a building on a service.NEC 250.28
Metal underground water pipe Tubería metálica subterránea para agua
Metal water pipe in contact with the earth for 10 feet or more. It counts as an electrode but must always be supplemented by another one.NEC 250.52(A)(1)Practice →
Separately derived system Sistema derivado separadoalso: sistema derivado por separado
A power source, such as a transformer or some generators, with no direct connection to the supply circuit conductors other than through grounding and bonding.NEC 250.30
Supply-side bonding jumper Puente de unión del lado del suministroalso: puente de unión del lado fuente
A bonding jumper on the line side of the service or a separately derived system's overcurrent device. It is sized from the ungrounded supply conductors.
System bonding jumper Puente de unión del sistema
The connection between the grounded conductor and the equipment grounding conductor at a separately derived system, such as a transformer.NEC 250.30(A)(1)

Overcurrent protection

Available fault current Corriente de falla disponiblealso: corriente de cortocircuito disponible
The largest current that could flow at a point during a short circuit. Service equipment in other than dwellings must be marked with it.NEC 110.24
Circuit breaker Interruptor automáticoalso: breaker, pastilla
A device that opens a circuit automatically on overcurrent and can be reset and used again. In Mexico it is often called pastilla termomagnética.NEC Article 100Practice →
Dual-element time-delay fuse Fusible de doble elementoalso: fusible de acción retardada
A fuse that rides through short inrush currents such as motor starting but still opens fast on a short circuit.NEC Table 430.52Practice →
Fuse Fusible
A device with a metal link that melts and opens the circuit on overcurrent. It must be replaced after it operates.NEC Article 100Practice →
Ground-fault protection of equipment (GFPE) Protección de equipos contra fallas a tierra
Protection that opens all ungrounded conductors at a set ground-fault level to prevent equipment damage. It is required on certain large solidly grounded wye services.NEC 230.95
Instantaneous trip circuit breaker Interruptor automático de disparo instantáneoalso: breaker solo magnético
A breaker with no intentional delay, used only as part of a listed motor controller combination.Practice →
Interrupting rating Capacidad de interrupciónalso: capacidad interruptiva
The highest current at rated voltage that a fuse or breaker can safely interrupt. It must be at least the available fault current.NEC 110.9
Inverse time circuit breaker Interruptor automático de tiempo inversoalso: termomagnético
A breaker that trips faster as current rises. This is the ordinary thermal-magnetic breaker.NEC Table 430.52Practice →
Next higher standard rating Tamaño estándar inmediato superioralso: regla del siguiente tamaño
When a conductor's ampacity does not match a standard size, the next higher OCPD is allowed up to 800 A, with conditions.NEC 240.4(B)Practice →
Nontime-delay fuse Fusible sin retardoalso: fusible de acción rápida
A fuse with no built-in delay, which opens quickly on any large overcurrent.NEC Table 430.52Practice →
Overcurrent Sobrecorriente
Any current above the rating of equipment or the ampacity of a conductor. It can come from an overload, a short circuit or a ground fault.NEC Article 100Practice →
Overcurrent protective device (OCPD) Dispositivo de protección contra sobrecorrientealso: protección contra sobrecorriente
A fuse or circuit breaker that opens a circuit on overcurrent to protect conductors and equipment.NEC Article 240Practice →
Overload Sobrecarga
Running equipment or a conductor above its rating long enough to cause damaging heat. A short circuit or ground fault is not an overload.NEC Article 100Practice →
Short circuit Cortocircuitoalso: corto
A low-resistance connection between conductors at different voltages, causing very high current.
Short-circuit current rating (SCCR) Corriente nominal de cortocircuitoalso: valor nominal de corriente de cortocircuito
The fault current an assembly such as a panel or control panel can withstand when protected as specified.NEC 110.10
Small conductor rule Regla de conductores pequeños
Overcurrent limits for small copper conductors: 15 A for 14 AWG, 20 A for 12 AWG and 30 A for 10 AWG, unless another article allows more.NEC 240.4(D)Practice →
Standard ampere ratings Capacidades nominales estándaralso: tamaños estándar de breakers y fusibles
The list of standard fuse and breaker sizes, such as 15, 20, 25, 30, 35, 40, 45, 50, 60 and 70 A.NEC 240.6(A)Practice →
Tap conductor Conductor de derivaciónalso: derivación (tap)
A conductor protected at a higher rating than its ampacity, allowed only under the tap rules for length and termination.NEC 240.21

Services and feeders

Branch circuit Circuito derivado
The conductors between the final overcurrent device and the outlets.NEC Article 100Practice →
Building disconnecting means Medio de desconexión del edificio
The disconnect required at a separate building or structure supplied by a feeder or branch circuit.NEC 225.31
Drip loop Gaza de goteoalso: bucle de goteo
A downward loop in service conductors below the service head so rainwater drips off instead of entering the raceway.NEC 230.54
Emergency disconnect Medio de desconexión de emergencia
An outdoor, readily accessible disconnect for one- and two-family dwellings so first responders can shut off power.
Feeder Alimentador
The conductors between the service or another power source and the final branch-circuit overcurrent device.NEC Article 100Practice →
Individual branch circuit Circuito derivado individual
A branch circuit that supplies only one piece of utilization equipment.NEC Article 100
Multiwire branch circuit Circuito derivado multiconductor
A branch circuit with two or more ungrounded conductors sharing one neutral. Its breakers must open all ungrounded conductors together.NEC 210.4
Overhead service conductors Conductores aéreos de acometida
Customer-side overhead conductors from the service point to the first connection with the service-entrance conductors.NEC Article 100
Service Acometidaalso: servicio eléctrico
The conductors and equipment that deliver power from the serving utility to the premises wiring.NEC Article 100Practice →
Service clearances Distancias libres de la acometidaalso: alturas mínimas
Minimum heights of overhead service conductors above roofs, driveways, sidewalks and streets.NEC 230.24
Service disconnecting means Medio de desconexión de la acometidaalso: interruptor principal
The switch or breaker that disconnects all building conductors from the service. It must be readily accessible, outside or nearest the point where conductors enter.NEC 230.70
Service drop Acometida aéreaalso: bajada de acometida
The overhead conductors between the utility's system and the service point.NEC Article 100
Service equipment Equipo de acometida
The main breaker or switch and fuses at the end of the service conductors that serve as the main control and cutoff of the supply.NEC Article 100
Service head Mufaalso: capuchón de acometida
The rain-resistant fitting at the top of a service raceway or cable where overhead conductors enter. Electricians call it the weatherhead.NEC 230.54
Service lateral Acometida subterránea
The underground conductors between the utility's system and the service point.NEC Article 100
Service point Punto de acometida
The point where the utility's wiring ends and the premises wiring begins. The utility usually decides where it is.NEC Article 100
Service-entrance conductors Conductores de entrada de acometida
The service conductors between the end of the service drop, lateral or overhead conductors and the service equipment.NEC Article 100Practice →
Temporary wiring Instalación provisional
Wiring for construction, remodeling, holiday lighting or emergencies, allowed for a limited time. Receptacles for workers need GFCI protection.NEC Article 590

Motors and controls

Adjustable-speed drive Variador de frecuenciaalso: variador de velocidad (VFD)
Power electronics that change the frequency and voltage supplied to a motor to control its speed.NEC Article 100
Controller Controlador
A device or group of devices that controls the electric power to the equipment it serves, such as a starter or switch for a motor.NEC Article 100
Disconnecting means Medio de desconexiónalso: desconectador
A device or group of devices that can disconnect the conductors of a circuit from their source.NEC Article 100
Full-load current (FLC) Corriente a plena carga
The motor current listed in NEC Tables 430.247 to 430.250 by horsepower and voltage. It is used to size conductors, OCPD and disconnects, not the nameplate value.NEC 430.6(A)(1)Practice →
Generator Generadoralso: planta de emergencia, planta de luz
A machine that turns mechanical energy into electricity. Its output conductors are generally sized at 115% of nameplate current.NEC Article 445
Hermetic refrigerant motor-compressor Motocompresor hermético de refrigeración
A compressor and motor sealed in the same housing, as in air conditioners and heat pumps.NEC Article 440
Horsepower Caballos de fuerza (hp)
The output rating of a motor. One horsepower equals 746 watts of mechanical output.NEC Article 430Practice →
In sight from A la vista de
Visible and no more than 50 feet away. A motor disconnect generally must be in sight from the motor and the controller.NEC Article 100
Locked-rotor current Corriente de rotor bloqueadoalso: corriente de arranque
The current a motor draws at start or when stalled, often around six times its full-load current.NEC Table 430.7(B)
Maximum overcurrent protection (MOCP) Protección máxima contra sobrecorriente
The largest fuse or breaker allowed for A/C equipment, printed on its nameplate. Going above it violates the listing.NEC Article 440
Minimum circuit ampacity (MCA) Ampacidad mínima del circuito
The conductor ampacity printed on A/C nameplates. Size the branch-circuit conductors from it.NEC Article 440
Motor branch-circuit conductors Conductores del circuito derivado del motor
Conductors that supply a single continuous-duty motor must have an ampacity of at least 125% of its full-load current.NEC 430.22Practice →
Motor branch-circuit short-circuit and ground-fault protection Protección del circuito derivado del motor contra cortocircuito y falla a tierra
The fuse or breaker that protects a motor circuit against shorts and ground faults. It is sized as a percentage of FLC from Table 430.52 and may be larger than the conductor ampacity.NEC 430.52Practice →
Motor feeder Alimentador de motores
A feeder supplying several motors, sized at 125% of the largest motor's FLC plus the FLC of all the others plus other loads.NEC 430.24Practice →
Motor overload protection Protección contra sobrecarga del motoralso: relevador de sobrecarga (térmico)
A device, often heaters or an electronic relay in the starter, that protects the motor and its conductors from overheating during running overloads.NEC 430.32Practice →
Motor starter Arrancadoralso: arrancador magnético
A controller with a contactor and overload relay that starts and stops a motor.NEC Article 430
Nameplate current (FLA) Corriente de placa (FLA)also: corriente nominal de placa de datos
The full-load amperes printed on the motor nameplate. It is used to size overload protection.NEC 430.6(A)(2)Practice →
Rated-load current (RLA) Corriente de carga nominal
The current of a hermetic motor-compressor at rated load, as marked by the equipment maker.NEC Article 440
Service factor Factor de servicio
A multiplier showing how much overload a motor can handle continuously. With a service factor of 1.15 or more, overloads may be sized at 125% of nameplate current.NEC 430.32(A)(1)Practice →
Temperature rise Aumento de temperaturaalso: elevación de temperatura
How much hotter than ambient the motor runs at full load. A marked rise of 40°C or less allows overloads at 125% of nameplate current.NEC 430.32(A)(1)Practice →

Transformers

Buck-boost transformer Transformador reductor-elevadoralso: buck-boost
A small transformer wired as an autotransformer to raise or lower voltage a few percent, such as 208 V to 230 V.
kVA rating Capacidad en kVAalso: potencia nominal en kVA
The apparent power a transformer can deliver. Full-load current is kVA × 1,000 ÷ voltage, also divided by 1.732 for three-phase.Practice →
Percent impedance Impedancia porcentual (%Z)
A nameplate value that tells how much a transformer limits fault current. Lower impedance means more available fault current.
Primary winding Devanado primarioalso: primario
The winding connected to the supply.Practice →
Secondary winding Devanado secundarioalso: secundario
The winding connected to the load.Practice →
Step-down transformer Transformador reductor
A transformer whose secondary voltage is lower than its primary voltage, such as 480 V to 208Y/120 V.Practice →
Transformer Transformador
A device with no moving parts that changes AC voltage up or down through magnetic coupling between windings.NEC Article 450Practice →
Transformer overcurrent protection Protección contra sobrecorriente del transformador
Fuses or breakers sized as a percentage of the transformer's rated currents, on the primary alone or on both primary and secondary.NEC 450.5(B)Practice →
Transformer secondary conductors Conductores del secundario del transformador
Conductors from a transformer secondary, which may run limited distances to their overcurrent device under the secondary conductor rules.NEC 240.21(C)Practice →
Turns ratio Relación de transformaciónalso: relación de vueltas
The ratio of primary to secondary turns, which sets the voltage ratio. Current changes in the opposite direction.Practice →

Load calculations

Clothes dryer Secadora de ropa
An electric dryer is counted at 5,000 W or its nameplate rating, whichever is larger, with demand factors for five or more dryers.NEC Article 120
Commercial kitchen equipment Equipo de cocina comercial
Cooking and other kitchen equipment in restaurants and similar places. Three or more units may take a demand factor, but never below the two largest loads.NEC Article 120
Continuous load Carga continua
A load whose maximum current is expected to last 3 hours or more. Conductors and OCPD are generally sized at 125% of it.NEC Article 100Practice →
Counter-mounted cooking unit Parrilla eléctrica empotradaalso: estufa de empotrar (cooktop)
A cooktop built into a counter. In load calculations it is treated with the range demand rules.NEC Article 120
Demand factor Factor de demanda
The ratio of the maximum demand of a system to its total connected load, used because not everything runs at once.NEC Article 100Practice →
Dwelling unit Unidad de viviendaalso: unidad habitacional
One or more rooms used as a home by one or more people, with permanent provisions for living, sleeping, cooking and sanitation.NEC Article 100Practice →
Fastened-in-place appliance Aparato fijo en su lugaralso: aparatos fijos
An appliance such as a dishwasher, disposal or water heater that is attached in place. Four or more in a dwelling may take a 75% demand factor.NEC Article 120Practice →
General lighting load Carga de alumbrado general
A load figured from floor area times a volt-ampere-per-square-foot value for the occupancy type, with demand factors applied.NEC Article 120Practice →
Household range Estufa eléctricaalso: cocina eléctrica
A freestanding electric cooking appliance. Its load comes from the range demand table, often 8 kW for one range of 12 kW or less.NEC Article 120
Laundry branch circuit Circuito derivado para lavanderíaalso: circuito de la lavadora
A 20 A circuit for the laundry receptacle in a dwelling, counted at 1,500 VA in the load calculation.NEC 210.11(C)(2)Practice →
Load calculation Cálculo de cargas
The NEC method for finding the minimum size of a service, feeder or branch circuit from the connected loads and demand factors.NEC Article 120Practice →
Multifamily dwelling Vivienda multifamiliaralso: edificio de departamentos
A building with three or more dwelling units.NEC Article 100
Neutral load Carga del neutroalso: desequilibrio máximo
The maximum unbalanced load between the neutral and any ungrounded conductor. Some loads, such as ranges and dryers, may be reduced for the neutral.NEC Article 120
Noncoincident loads Cargas no coincidentes
Loads that do not run at the same time, such as heating and air conditioning. Only the larger one is counted.NEC Article 120Practice →
Noncontinuous load Carga no continua
A load that does not run at full current for 3 hours or more. It is counted at 100% when sizing conductors and OCPD.Practice →
Optional method Método opcional
A simpler dwelling calculation that takes most loads at a single demand percentage. Use it on the exam only when the question says so.NEC Article 120Practice →
Receptacle load Carga de receptáculosalso: carga de contactos
In non-dwelling calculations, each single or multiple receptacle on one yoke counts 180 VA, and a demand factor applies above 10 kVA.NEC Article 120Practice →
Show window Aparadoralso: escaparate, vitrina
A window used to display goods or advertising, usually open or partly open at the back. Its lighting load is figured per linear foot of window.NEC Article 100Practice →
Sign outlet Salida para letreroalso: salida para anuncio
A commercial building with ground-floor pedestrian access needs an outlet for a sign, counted at 1,200 VA minimum in the load calculation.Practice →
Small-appliance branch circuit Circuito derivado para pequeños aparatos
A 20 A circuit for kitchen, dining and pantry receptacles in a dwelling. At least two are required, each counted at 1,500 VA in the load calculation.NEC 210.11(C)(1)Practice →
Standard method Método estándaralso: método general
The step-by-step NEC load calculation with separate demand factors for lighting, appliances, cooking, dryers and HVAC.NEC Article 120Practice →
Unit load Carga unitariaalso: VA por pie cuadrado
The VA per square foot assigned to each occupancy type for the general lighting calculation.NEC Article 120Practice →
Wall-mounted oven Horno de paredalso: horno empotrado
An oven built into a wall. A cooktop and up to two ovens in the same room may be added together and treated as one range.NEC Article 120
Water heater Calentador de aguaalso: boiler
A storage water heater of 120 gallons or less is treated as a continuous load, so its branch circuit is rated at least 125% of the nameplate.Practice →

Devices and equipment

Appliance Aparatoalso: electrodoméstico
Utilization equipment, usually not industrial, built in standard sizes for jobs such as cooking, laundry or cooling.NEC Article 100Practice →
Arc-fault circuit interrupter (AFCI) Interruptor de circuito por falla de arcoalso: ICFA, AFCI
A device that detects the signature of a dangerous arc and opens the circuit to prevent fires.NEC 210.12
Bathroom Cuarto de bañoalso: baño
An area with a basin plus a toilet, tub, shower, urinal or bidet. Bathroom receptacles need GFCI protection.NEC Article 100
Damp location Lugar húmedo
A protected location exposed to some moisture, such as under a roofed open porch or in some basements.NEC Article 100
Device Dispositivo
A part of the wiring system that carries or controls current but does not use it, such as a switch or receptacle.NEC Article 100
Enclosure Envolventealso: caja, gabinete
The case or housing of equipment that keeps people from touching live parts and protects the equipment.NEC Article 100
Ground bar Barra de tierras
The terminal bar, bonded to the enclosure, where equipment grounding conductors land.Practice →
Ground-fault circuit interrupter (GFCI) Interruptor de circuito por falla a tierraalso: ICFT, GFCI
A device that de-energizes a circuit when current leaking to ground goes over a small set value (about 4 to 6 mA), to protect people from shock.NEC 210.8
Kitchen Cocina
An area with a sink and permanent provisions for preparing and cooking food. The definition matters for GFCI and receptacle rules.NEC Article 100
Load center Centro de cargaalso: panel residencial
The trade name for a residential or light-commercial panelboard with plug-in breakers.NEC Article 408
Luminaire Luminariaalso: luminario
A complete lighting unit with its light source, parts to position and protect it, and connection to power.NEC Article 100
Multioutlet assembly Ensamble de salidas múltiplesalso: multicontacto
A surface or flush raceway with receptacles along it. In loads it counts 180 VA per 5 feet, or per foot where many appliances run at once.NEC Article 380Practice →
Neutral bar Barra de neutros
The terminal bar where grounded (neutral) conductors land. It is bonded to the enclosure only at the service or a separately derived system.
Outlet Salida
A point in the wiring system where current is taken to supply utilization equipment, such as a receptacle or luminaire outlet.NEC Article 100
Panelboard Tablero de alumbrado y controlalso: panel, tablero
A panel with buses and overcurrent devices for lighting, heat or power circuits, placed in a cabinet and reachable only from the front.NEC Article 408
Receptacle Receptáculoalso: contacto, tomacorriente
A contact device installed at an outlet for connecting an attachment plug. A duplex receptacle is two receptacles on one yoke.NEC Article 100Practice →
Safety switch Interruptor de seguridadalso: desconectador de cuchillas
An enclosed knife switch, fused or not, used as a disconnecting means for equipment or a service.
Surge protective device (SPD) Dispositivo de protección contra sobretensiones (SPD)also: supresor de picos
A device that limits transient voltage spikes by diverting surge current. Dwelling services now require one.
Switchboard Tablero de distribuciónalso: switchboard
A large freestanding panel or assembly of panels with switches, overcurrent devices and buses, usually reachable from the front and rear.NEC Article 408
Tamper-resistant receptacle Receptáculo a prueba de manipulaciones (TR)also: receptáculo resistente a la manipulación
A receptacle with shutters that block objects from being pushed into one slot. Required in dwellings and many other places.NEC Article 406
Three-way switch Apagador de tres víasalso: apagador de escalera
A switch used in pairs to control a light from two places.NEC Article 404
Transfer switch Interruptor de transferenciaalso: desconectador de transferencia, transferencia
An automatic or manual switch that moves loads from one power source to another, such as from the utility to a generator, without connecting the two.NEC Article 100
Weather-resistant receptacle Receptáculo resistente a la intemperie (WR)
A receptacle built to resist moisture and UV, required for 15 A and 20 A receptacles in damp and wet locations.NEC 406.9
Wet location Lugar mojado
A location exposed to weather, saturated with water, or underground, including the inside of underground raceways.NEC Article 100
Yoke Yugoalso: soporte del dispositivo
The metal mounting strap of a device. Each yoke counts as two conductors of the largest size connected to it in box fill.NEC 314.16(B)Practice →

Special occupancies

Class I location Área Clase Ialso: gases y vapores inflamables
A hazardous location where flammable gases, vapors or liquid-produced vapors may be present in ignitible amounts.NEC 500.5(B)
Class II location Área Clase IIalso: polvos combustibles
A hazardous location made dangerous by combustible dust, such as grain elevators.NEC 500.5(C)
Conduit seal Selloalso: accesorio sellador
A fitting filled with sealing compound that stops gases and flames from traveling through conduit in a Class I location.NEC 501.15
Division 1 División 1
A hazardous location where the hazard is likely present during normal operation.NEC 500.5
Division 2 División 2
A hazardous location where the hazard is present only under abnormal conditions, such as a leak or equipment failure.NEC 500.5
Electric vehicle supply equipment (EVSE) Equipo de suministro para vehículo eléctrico (EVSE)also: cargador de vehículo eléctrico
The equipment that delivers power to an electric vehicle, commonly called the charger. EV charging loads are treated as continuous.NEC Article 625
Emergency system Sistema de emergencia
A legally required system that supplies power for life safety, such as exit and egress lighting, within 10 seconds of losing normal power.NEC Article 700
Energy storage system (ESS) Sistema de almacenamiento de energíaalso: baterías
Batteries or other equipment that store energy and supply it later, often paired with PV.NEC Article 706
Equipotential bonding Unión equipotencial
Bonding pool steel, metal parts, deck and water together, usually with 8 AWG solid copper, so no dangerous voltage difference exists.NEC 680.26
Explosionproof equipment Equipo a prueba de explosión
Equipment in an enclosure that can contain an internal explosion and cool escaping gases so the surrounding atmosphere does not ignite.NEC Article 100
Hazardous (classified) location Área peligrosa (clasificada)also: lugar peligroso
A place where fire or explosion hazards exist from flammable gases, vapors, combustible dust or ignitible fibers.NEC Article 500
Information technology equipment room Sala de equipo de tecnología de la informaciónalso: cuarto de cómputo
A room for computers and data equipment that may use special wiring under a raised floor and a remote disconnect.NEC Article 645
Inverter Inversor
Equipment that changes DC from PV modules or batteries into AC.NEC Article 690
Legally required standby system Sistema de reserva legalmente requerido
A standby system required by law for loads that could create hazards or hamper rescue if power is lost, restored within 60 seconds.NEC Article 701
Manufactured home Casa prefabricadaalso: vivienda manufacturada
A factory-built dwelling transported in sections and set on site, built to the federal standard for manufactured housing.NEC Article 550
Marina Marinaalso: puerto deportivo
A facility for mooring boats, with rules for shore power receptacles, ground-fault protection and wiring over water.NEC Article 555
Mobile home Casa móvilalso: tráiler
A factory-built home on a permanent chassis that can be moved and is used as a dwelling with or without a permanent foundation.NEC Article 550
Motor fuel dispensing facility Gasolineraalso: estación de servicio
A place where fuel is dispensed into vehicles. Areas around the dispensers and tanks are classified as hazardous.NEC Article 514
Optional standby system Sistema de reserva opcional
A standby generator system the owner chooses to install, such as a home backup generator.NEC Article 702
Photovoltaic (PV) system Sistema solar fotovoltaicoalso: paneles solares
A system of solar modules, wiring and inverters that turns sunlight into electricity.NEC Article 690
Rapid shutdown Apagado rápido
A PV function that lowers the voltage of conductors on or in a building within seconds so firefighters can work safely.NEC 690.12
Recreational vehicle (RV) Vehículo de recreo (RV)also: vehículo recreativo, motorhome
A vehicle-type unit used as temporary living quarters for camping or travel, such as a motor home or travel trailer.NEC Article 551
RV park Estacionamiento para vehículos de recreoalso: parque de RV
A lot with RV sites. Article 551 sets the site receptacles (20, 30 and 50 A) and the demand factors for the park's service.NEC Article 551
Signs and outline lighting Letreros eléctricos e iluminación de contornosalso: anuncios luminosos
Electric signs and lighting that outlines buildings, with rules for disconnects, branch circuits and listing.NEC Article 600
Spa or hot tub Spa o tina de hidromasajealso: jacuzzi
A hydromassage pool for recreation that is not drained after each use.NEC Article 680
Special occupancies Ocupaciones especialesalso: ambientes especiales
NEC Chapter 5 locations with extra rules, such as hazardous areas, health care, assembly, mobile homes, RVs and marinas.
Swimming pool Albercaalso: piscina
A permanently installed or storable pool. Article 680 covers its wiring, bonding, GFCI protection and clearances.NEC Article 680
Wet-niche luminaire Luminaria de nicho húmedo
An underwater pool light installed in a forming shell, with water around it.NEC 680.23

Safety, licensing and the exam

Apprentice electrician Aprendiz de electricistaalso: aprendiz
A registered learner who works under licensed electricians. Texas apprentices need no exam but renew yearly with 4 hours of CE or enrollment in an apprenticeship program.
Approved Aprobado
Acceptable to the authority having jurisdiction.NEC Article 100
Arc flash Relámpago de arcoalso: arco eléctrico
A burst of heat and light from an electric arc through air. Equipment likely to be worked on while energized needs an arc-flash warning label.NEC 110.16
Authority having jurisdiction (AHJ) Autoridad competentealso: inspector
The organization, office or person who enforces the code and approves equipment and installations, usually the electrical inspector.NEC Article 100
Calculations exam Examen de cálculos
The separate calculations portion of the Texas journeyman and master exams. Each portion must be passed with 70%.
Candidate Information Bulletin Boletín Informativo para Candidatos
The PSI booklet that lists exam content, rules, fees, allowed references and how to schedule.
Continuing education Educación continua
Training required to renew a license. Most Texas electrician licenses need 4 hours per license term covering the NEC, state law and rules, and safety.
Electrical contractor Contratista eléctrico
A business licensed by TDLR to do electrical work for the public. It needs no exam but must have a master electrician of record and insurance.
Exception Excepción
A stated case where a rule does not apply or applies differently. On the Texas exam, do not use exceptions unless the question tells you to.
Informational note Nota informativa
Explanatory material in the NEC that is not an enforceable requirement.NEC 90.5(C)
Journeyman electrician Electricista oficial
A Texas license for electricians who have 8,000 hours of experience under a master electrician and pass the TDLR exam. A journeyman works under a master's supervision.
Journeyman industrial electrician Oficial electricista industrial
A Texas license limited to industrial sites such as plants, refineries, pipelines and oil and gas facilities.
Listed Listadoalso: certificado
Included in a list from a testing organization, such as UL, showing the product meets a standard for a stated use.NEC Article 100
Lockout/tagout Bloqueo y etiquetadoalso: candadeo
Locking a disconnect open and tagging it so no one can re-energize the circuit while someone works on it.
Maintenance electrician Electricista de mantenimiento
A Texas license for maintaining and repairing existing electrical systems on premises the employer owns or manages.
Mandatory rule Regla obligatoria
A code requirement using the words shall or shall not.NEC 90.5(A)
Master electrician Maestro electricistaalso: electricista maestro
The top Texas electrician license. It requires holding a journeyman license for two years, 12,000 hours of experience and passing the master exam.
National Electrical Code (NEC) Código Eléctrico Nacional (NEC)also: NFPA 70
The model electrical installation code published by NFPA as NFPA 70. Texas has used the 2026 edition since September 1, 2026.
NEC knowledge exam Examen de conocimientos del NEC
The code-knowledge portion of the Texas journeyman and master exams, separate from the calculations portion.
NFPA 70E NFPA 70Ealso: norma de seguridad eléctrica en el trabajo
The standard for electrical safety in the workplace, covering shock and arc-flash protection and safe work practices.
Open book exam Examen a libro abierto
A test where you may use your own NEC. Texas allows a soft-bound 2026 NEC with highlighting, notes and publisher-made permanent tabs, but no homemade tabs.
Personal protective equipment (PPE) Equipo de protección personal (EPP)
Gear such as rated gloves, face shields and arc-rated clothing that protects workers from shock and arc flash.
PSI PSIalso: empresa de exámenes PSI
The testing company that gives the Texas electrician exams at its test centers. It offers the exams in English or Spanish at no extra cost.
Qualified person Persona calificada
Someone with the skills, knowledge and safety training to work on electrical equipment and recognize its hazards.NEC Article 100
Readily accessible Fácilmente accesiblealso: de fácil acceso
Reachable quickly for operation or inspection without tools, ladders or moving obstacles.NEC Article 100
Residential wireman Instalador eléctrico residencialalso: electricista residencial
A Texas license for wiring one- and multifamily dwellings up to four stories. It requires 4,000 hours or an approved program, plus the exam.
TDLR TDLR (Departamento de Licencias y Regulación de Texas)
The Texas Department of Licensing and Regulation, the state agency that licenses electricians and sets the exam rules.
Working space Espacio de trabajo
The clear space required in front of equipment that may be serviced while energized, at least 30 inches wide, with depth set by voltage.NEC 110.26

Spanish technical terms follow NOM-001-SEDE (Mexico's code, which uses the NEC article numbers) and US industry usage; job-site words are listed as "also". NEC references are there so you can open your own 2026 book.